A strong self-adhesive all-in-one heating mat which ensures a quick and easy installation directly on the existing floor. It can be covered with a self-levelling floor screed onto which the top floor can be laid in the usual way.
The system consists of a thin 4 mm thick twin conductor electric heating cable attached to an open weave fibre glass mesh, with self-adhesive on the entire surface of the mat.
Features and benefits:
- Easy to install.
- Low installation height.
- Long life-time.
- 100% screened.
- 12-year warranty.
- Compliant with IEC60335-2-96.
- Applications:
- The low installation height is especially suited to renovations.
Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Impey Showers is consulted before specifying.
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 50 W | |
| Horizontal Resistance (?) | 1058 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 0.5 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 1000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030500 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 100 W | |
| Horizontal Resistance (?) | 529 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 1 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 2000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030502 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 150 W | |
| Horizontal Resistance (?) | 352 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 1.5 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 3000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030504 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 200 W | |
| Horizontal Resistance (?) | 264 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 2 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 4000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030506 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 250 W | |
| Horizontal Resistance (?) | 211 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 2.5 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 5000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030508 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 300 W | |
| Horizontal Resistance (?) | 176 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 3 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 6000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030510 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 350 W | |
| Horizontal Resistance (?) | 151 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 3.5 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 7000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030512 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 400 W | |
| Horizontal Resistance (?) | 132 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 4 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 8000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030514 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 500 W | |
| Horizontal Resistance (?) | 105 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 5 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 10000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030516 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 600 W | |
| Horizontal Resistance (?) | 88.1 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 6 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 12000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030518 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 700 W | |
| Horizontal Resistance (?) | 75.5 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 7 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 14000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030520 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 800 W | |
| Horizontal Resistance (?) | 66.1 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 8 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 16000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030522 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 900 W | |
| Horizontal Resistance (?) | 58.7 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 9 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 18000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030524 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 1000 W | |
| Horizontal Resistance (?) | 52.9 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 10 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 20000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030526 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |
|
|
||
| Ambient Temperature (?) | 65 °C | |
| Effect (at 230 V) (?) | 1200 W | |
| Horizontal Resistance (?) | 44.1 Ohm | |
| IP Rating (?) | IP X7 | |
| Max UFH Heat Output (?) | 100 W/m² | |
| Minimum Installation Temperature (?) | -5 °C | |
| Pulling Strength (?) | 120 N | |
| Voltage AC (?) | 220 - 240 VAC | |
|
|
||
| Construction (?) | One cold lead , Round , Twin conductor with screen | |
| Deformation Strength (?) | 600 N | |
|
|
||
| Area (?) | 12 m2 | |
| Cable Thickness (?) | 4 mm | |
| Length (?) | 24000 mm | |
| Width (?) | 500 mm | |
|
|
||
| Product ID Number (?) | 83030528 | |
| Typical Building Zone (?) | Wetrooms | |
| Warranty (?) | 12 years | |
|
|
||
| Cold Lead Spec (?) | 2 x 1.0 mm2,4 m DTWB,Earthed | |
| Material (?) | Alu-foil , FEP , Lead , PVC , Tinned copper | |
|
|
||
| Uniclass (?) | Ss_60_40_92 Underfloor heating and cooling systems | |