Thermally broken, sound reducing, security rated Curtain Walling & Facades

Thermfix VARIO 45mm - Vertical Fire Rated, non-fire rated & Security rated

This system for thermally insulated curtain Walls is based on a mullion/transom construction. Very narrow facing widths from 45 mm permit a wide range of applications such as Fire Protection and burglary resistance.

The internal side profiles made from Steel or Stainless Steel take the load bearing function. Thanks to excellent static properties, impressive field sizes are possible with very narrow profile face widths.

https://youtu.be/WM07VeRkVio

Thermally Insulated Doors and Windows from the systems Forster UNICO and UNICO XS can be integrated within this system.

**Due to the wide range of variations for each of our products it is impossible to capture everything on one website. Therefore we always recommend speaking with one of our Technical Team for further advice, technical details, specifications, U-value calculations, sizes & acoustic ratings that may be more specific to your project.

**Please contact for Stainless Steel options.



Specification Details

Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Forster Profile Systems (UK) Ltd is consulted before specifying.

Forster Profile Systems (UK) Ltd
111 Hollymoor Way, Northfield
Birmingham
England
B31 5HE
P: 01909 295 000

Thermally broken, sound reducing, security rated Curtain Walling & Facades

E30
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

E60
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

E90
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

E120
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

EI30
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

EI60
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: BS 476, EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling

EI90
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

EI120
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, fire rated curtain walling, fire rated facade, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

NON FIRE RATED
• British Standards: BS 476
• CE Marking: Yes
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1634-1, ENV 13050, ISO 140-3
• Material: Stainless steel, Steel
• Uniclass: Ss_25_10_20 Curtain walling systems
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Product Type: curtain walling, facade, facades, Vertical Curtain Walling

NON FR SECURITY RATED
• British Standards: BS 476
• CE Marking: Yes
• Security Rating: RC1, RC2, RC3, FB4 NS
• Standards: EN 10077-1, EN 12152, EN 12153, EN 12154, EN 12155, EN 12179, EN 12412-2, EN 13050, EN 13116, EN 13501-1, EN 13501-2, EN 1364-4, EN 13830, EN 14019, EN 1522, EN 1523, EN 1627, EN 1628, EN 1629, EN 1630, EN 1634-1, ENV 13050, ISO 140-3
• Product Type: curtain walling, facade, facades, Vertical Curtain Walling
• Impact Resistance (Code): Class E5 / I5
• Thermal Resistance: 0.49 m2K/W
• Water Tightness: 1125 Pa
• Material: Steel
• Uniclass: Ss_25_10_20 Curtain walling systems

File Downloads