Through Fix System (TFS1) A2 Rainscreen System - A2 Fire Rated Aluminium Cladding (CWCT Tested)

For facades where an element of adjustment is required an Eltherington through-fix rainscreen cladding system is the best choice.

Our through fix system offers an adjustable void depth and is therefore able to accommodate a range of insulation thicknesses, whilst overcoming any irregularities in the substrate.

That makes the rainscreen cladding solution ideal where the variances in quality of infill material on existing buildings dictate that fixings can only be secured at certain points across the facade, for example, at floor slabs.

Eltherington through-fix systems are designed so that the fixings are minimally visible across the facade, being masked by the shadow-lines between the panels. From a distance, this maintains the sheer, architectural appearance of the facade.

  • Horizontal joint - 20mm
  • Fixings - Self drill mechanical fixings
  • Rail centres - 600mm max
  • Install method - 1st & 2nd fix layout
  • CWCT tested with Hilti-Eurofox


Specification Details

Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Eltherington Group is consulted before specifying.

Eltherington Group
Eltherington Group
Hull
United Kingdom
HU9 5QD
P: 07867424063

Through Fix System (TFS1) A2 Rainscreen System - A2 Fire Rated Aluminium Cladding (CWCT Tested)

TFS1 - 5.4 [2mm]
• Max Length Tested: 2850 mm
• Max Width Tested: 580 mm
• Thickness: 2 mm
• Weight per m2: 5.4 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to Fire: A2
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 60
• Min Support Rail Cost £: 22
• Uniclass: Ss_25_20_70 Rainscreen cladding systems

TFS1 - 7.4 [2mm]
• Max Length Tested: 3850 mm
• Max Width Tested: 1450 mm
• Thickness: 2 mm
• Weight per m2: 7.4 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to Fire: B
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 65
• Min Support Rail Cost £: 22
• Uniclass: Ss_25_20_70 Rainscreen cladding systems

TFS1 - 10.1 [3mm]
• Max Length Tested: 4010 mm
• Max Width Tested: 998 mm
• Thickness: 3 mm
• Weight per m2: 10.1 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to Fire: B
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 75
• Min Support Rail Cost £: 22
• Uniclass: Ss_25_20_70 Rainscreen cladding systems

TFS1 - 10.8 [4mm]
• Max Length Tested: 2380 mm
• Max Width Tested: 1280 mm
• Thickness: 4 mm
• Weight per m2: 10.8 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to Fire: A2
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 80
• Min Support Rail Cost £: 22
• Uniclass: Ss_25_20_70 Rainscreen cladding systems